In optics, a Fabry–Pérot interferometer or etalon is typically made of a transparent plate with two reflecting surfaces, or two parallel highly reflecting mirrors. (Precisely, the former is an etalon and the latter is an interferometer, but the terminology is often used inconsistently.) Its transmission spectrum as a function of wavelength exhibits peaks of large transmission corresponding to resonances of the etalon. It is named after Charles Fabry and Alfred Perot.[1] "Etalon" is from the French étalon, meaning "measuring gauge" or "standard".[2]

Etalons are widely used in telecommunications, lasers and spectroscopy to control and measure the wavelengths of light. Recent advances in fabrication technique allow the creation of very precise tunable Fabry–Pérot interferometers.

Basic description

File:Fabry Perot Interferometer - diagram.png
Fabry–Pérot interferometer, using a pair of partially reflective, slightly wedged optical flats. The wedge angle is highly exaggerated in this illustration; only a fraction of a degree is actually necessary to avoid ghost fringes. Low-finesse versus high-finesse images correspond to mirror reflectivities of 4% (bare glass) and 95%.

The heart of the Fabry–Pérot interferometer is a pair of partially reflective glass optical flats spaced micrometers to centimeters apart, with the reflective surfaces facing each other. (Alternatively, a Fabry–Pérot etalon uses a single plate with two parallel reflecting surfaces.) The flats in an interferometer are often made in a wedge shape to prevent the rear surfaces from producing interference fringes; the rear surfaces often also have an anti-reflective coating.

In a typical system, illumination is provided by a diffuse source set at the focal plane of a collimating lens. A focusing lens after the pair of flats would produce an inverted image of the source if the flats were not present; all light emitted from a point on the source is focused to a single point in the system's image plane. In the accompanying illustration, only one ray emitted from point A on the source is traced. As the ray passes through the paired flats, it is multiply reflected to produce multiple transmitted rays which are collected by the focusing lens and brought to point A' on the screen. The complete interference pattern takes the appearance of a set of concentric rings. The sharpness of the rings depends on the reflectivity of the flats. If the reflectivity is high, resulting in a high Q factor, monochromatic light produces a set of narrow bright rings against a dark background. A Fabry–Pérot interferometer with high Q is said to have high finesse.

Applications

A picture of the solar corona taken with the LASCO C1 coronagraph which employed a tunable Fabry–Pérot interferometer to recover scans of the solar corona at a number of wavelengths near the FeXIV green line at 5308 Å. The picture is a color-coded image of the doppler shift of the line, which may be associated with the coronal plasma velocity towards or away from the satellite camera. In calculating the velocity, the velocity due to solar rotation has been subtracted.
A commercial Fabry-Perot device
  • Telecommunications networks employing wavelength division multiplexing have add-drop multiplexers with banks of miniature tuned fused silica or diamond etalons. These are small iridescent cubes about 2 mm on a side, mounted in small high-precision racks. The materials are chosen to maintain stable mirror-to-mirror distances, and to keep stable frequencies even when the temperature varies. Diamond is preferred because it has greater heat conduction and still has a low coefficient of expansion. In 2005, some telecommunications equipment companies began using solid etalons that are themselves optical fibers. This eliminates most mounting, alignment and cooling difficulties.
  • Dichroic filters are made by depositing a series of etalonic layers on an optical surface by vapor deposition. These optical filters usually have more exact reflective and pass bands than absorptive filters. When properly designed, they run cooler than absorptive filters because they can reflect unwanted wavelengths. Dichroic filters are widely used in optical equipment such as light sources, cameras, astronomical equipment, and laser systems.
  • Optical wavemeters and some optical spectrum analyzers use Fabry–Pérot interferometers with different free spectral ranges to determine the wavelength of light with great precision.
  • Laser resonators are often described as Fabry–Pérot resonators, although for many types of laser the reflectivity of one mirror is close to 100%, making it more similar to a Gires–Tournois interferometer. Semiconductor diode lasers sometimes use a true Fabry–Pérot geometry, due to the difficulty of coating the end facets of the chip.
  • Etalons are often placed inside the laser resonator when constructing single-mode lasers. Without an etalon, a laser will generally produce light over a wavelength range corresponding to a number of cavity modes, which are similar to Fabry–Pérot modes. Inserting an etalon into the laser cavity, with well-chosen finesse and free-spectral range, can suppress all cavity modes except for one, thus changing the operation of the laser from multi-mode to single-mode.
  • A Fabry–Pérot etalon can be used to make a spectrometer capable of observing the Zeeman effect, where the spectral lines are far too close together to distinguish with a normal spectrometer.
  • In gravitational wave detection, a Fabry–Pérot cavity is used to store photons for almost a millisecond while they bounce up and down between the mirrors. This increases the time a gravitational wave can interact with the light, which results in a better sensitivity at low frequencies. This principle is used by detectors such as LIGO and Virgo, which consist of a Michelson interferometer with a Fabry–Pérot cavity with a length of several kilometers in both arms. Smaller cavities, usually called mode cleaners, are used for spatial filtering and frequency stabilization of the main laser.

Theory

File:Etalon-2.svg
A Fabry–Pérot etalon. Light enters the etalon and undergoes multiple internal reflections.

The varying transmission function of an etalon is caused by interference between the multiple reflections of light between the two reflecting surfaces. Constructive interference occurs if the transmitted beams are in phase, and this corresponds to a high-transmission peak of the etalon. If the transmitted beams are out-of-phase, destructive interference occurs and this corresponds to a transmission minimum. Whether the multiply reflected beams are in phase or not depends on the wavelength (λ) of the light (in vacuum), the angle the light travels through the etalon (θ), the thickness of the etalon () and the refractive index of the material between the reflecting surfaces (n).

The phase difference between each successive transmitted pair (i.e. T2 - T1 in the diagram) is given by δ:[3]

\delta = \left( \frac{2 \pi}{\lambda} \right) 2 n \ell \cos\theta.

If both surfaces have a reflectance R, the transmittance function of the etalon is given by

T_e = \frac{(1 - R)^2}{1 - 2R\cos\delta + R^2} = \frac{1}{1 + F\sin^2\left(\frac{\delta}{2}\right)},

where

 F = \frac{4R}{{(1-R)^2}}

is the coefficient of finesse.

The transmission of an etalon as a function of wavelength. A high-finesse etalon (red line) shows sharper peaks and lower transmission minima than a low-finesse etalon (blue).

Maximum transmission (T_e = 1) occurs when the optical path length difference (2 n l \cos\theta) between each transmitted beam is an integer multiple of the wavelength. In the absence of absorption, the reflectance of the etalon Re is the complement of the transmittance, such that T_e + R_e = 1. The maximum reflectivity is given by:

R_\max = 1 - \frac{1}{1 + F} = \frac{4R}{(1 + R)^2}

and this occurs when the path-length difference is equal to half an odd multiple of the wavelength.

Finesse as a function of reflectivity. Very high finesse factors require highly reflective mirrors.

The wavelength separation between adjacent transmission peaks is called the free spectral range (FSR) of the etalon, Δλ, and is given by:

\Delta\lambda = \frac{ \lambda_0^2}{2n_\mathrm{g} \ell \cos\theta + \lambda_0 } \approx \frac{ \lambda_0^2}{2n_\mathrm{g} \ell \cos\theta }

where λ0 is the central wavelength of the nearest transmission peak and n_\mathrm{g} is the group refractive index.[citation needed] The FSR is related to the full-width half-maximum, δλ, of any one transmission band by a quantity known as the finesse:

 \mathcal{F} = \frac{\Delta\lambda}{\delta\lambda} = \frac{\pi}{2 \arcsin\left(\frac{1}{\sqrt F}\right)}.

This is commonly approximated (for R > 0.5) by

 \mathcal{F} \approx \frac{\pi \sqrt{F}}{2} = \frac{\pi R^\frac{1}{2} }{1 - R} .

If the two mirrors are not equal, the finesse becomes

 \mathcal{F} \approx \frac{\pi (R_1R_2)^\frac{1}{4} }{1 - (R_1R_2)^\frac{1}{2}} .

Etalons with high finesse show sharper transmission peaks with lower minimum transmission coefficients. In the oblique incidence case, the finesse will depend on the polarization state of the beam, since the value of "R", given by the Fresnel equations, is generally different for p and s polarizations.

A Fabry–Pérot interferometer differs from a Fabry–Pérot etalon in the fact that the distance between the plates can be tuned in order to change the wavelengths at which transmission peaks occur in the interferometer. Due to the angle dependence of the transmission, the peaks can also be shifted by rotating the etalon with respect to the beam.

Fabry–Pérot interferometers or etalons are used in optical modems, spectroscopy, lasers, and astronomy.

A related device is the Gires–Tournois etalon.

Detailed analysis

Lua error in package.lua at line 80: module 'strict' not found.

Fabry Perot Diagram1.svg

Two beams are shown in the diagram at the right, one of which (T0) is transmitted through the etalon, and the other of which (T1) is reflected twice before being transmitted. At each reflection, the amplitude is reduced by \sqrt R, while at each transmission through an interface the amplitude is reduced by \sqrt T. Assuming no absorption, conservation of energy requires T + R = 1. In the derivation below, n is the index of refraction inside the etalon, and n0 is that outside the etalon. It is presumed that n > n0. The incident amplitude at point a is taken to be one, and phasors are used to represent the amplitude of the radiation. The transmitted amplitude at point b will then be

t_0 = T\,e^{ik\ell/\cos\theta},

where k=2\pi n/\lambda is the wavenumber inside the etalon and λ is the vacuum wavelength. At point c the transmitted amplitude will be

t'_1 = TR\,e^{3ik\ell/\cos\theta}.

The total amplitude of both beams will be the sum of the amplitudes of the two beams measured along a line perpendicular to the direction of the beam. The amplitude t0 at point b can therefore be added to t'1 retarded in phase by an amount k_0 \ell_0 where k_0=2\pi n_0/\lambda is the wavenumber outside of the etalon. Thus

t_1 = TR\,e^{3ik\ell/\cos\theta-ik_0 \ell_0},

where ℓ0 is

\ell_0=2\ell\tan\theta\sin\theta_0\,.

The phase difference between the two beams is

\delta={2k\ell\over\cos\theta} - k_0 \ell_0\,.

The relationship between θ and θ0 is given by Snell's law:

n\sin\theta=n_0\sin\theta_0\,,

so that the phase difference may be written:

\delta=2k\ell\,\cos\theta\,.

To within a constant multiplicative phase factor, the amplitude of the mth transmitted beam can be written as:

t_m=TR^m e^{im\delta}\,.

The total transmitted amplitude is the sum of all individual beams' amplitudes:

t=\sum_{m=0}^\infty t_m=T\sum_{m=0}^\infty R^m\,e^{im\delta}

The series is a geometric series whose sum can be expressed analytically. The amplitude can be rewritten as

t=\frac{T}{1-Re^{i\delta}}.

The intensity of the beam will be just t times its complex conjugate. Since the incident beam was assumed to have an intensity of one, this will also give the transmission function:

T_e=tt^*=\frac{T^2}{1+R^2-2R\cos\delta}

For an asymmetrical cavity, that is, one with two different mirrors, the general form of the transmission function is

T_e=\frac{T_1T_2}{1+R_1R_2-2\sqrt{R_1R_2}\cos\delta}

Another expression for the transmission function

Defining \gamma = \ln\left(\frac{1}{R}\right) the above expression may be written as:

T_e=\frac{T^2}{1-R^2}\left(\frac{\sinh\gamma}{\cosh\gamma-\cos\delta}\right)

The second term is proportional to a wrapped Lorentzian distribution so that the transmission function may be written as a series of Lorentzian functions:

T_e=\frac{2\pi\,T^2}{1-R^2}\,\sum_{\ell=-\infty}^\infty L(\delta-2\pi\ell;\gamma)

where

L(x;\gamma) = \frac{\gamma}{\pi(x^2+\gamma^2)}

See also

Notes

  1. Perot frequently spelled his name with an accent—Pérot—in scientific publications, and so the name of the interferometer is commonly written with the accent. Lua error in package.lua at line 80: module 'strict' not found. Page 2: "Pérot ou Perot?"
  2. Oxford English Dictionary
  3. Lua error in package.lua at line 80: module 'strict' not found.

References

  • Lua error in package.lua at line 80: module 'strict' not found.

External links