Spiral computed tomography

From Infogalactic: the planetary knowledge core
(Redirected from Spiral CT)
Jump to: navigation, search
Spiral computed tomography
Diagnostics
MeSH D036542
[[[d:Lua error in Module:Wikidata at line 863: attempt to index field 'wikibase' (a nil value).|edit on Wikidata]]]

Spiral computed tomography is a computed tomography[1] technology involving movement in a helical pattern for the purpose of increasing resolution. Most modern hospitals currently use spiral CT scanners.

CT beam types have included parallel beams, fan-beams, and cone-beams.[2]

SSCT and MSCT

Willi Kalender, who is credited with the invention prefers the term Spiral scan CT,[3] arguing that spiral is synonymous with helical: for example as used in 'spiral staircase'.[4]

Since its invention by Kalender in the 1980s, helical scan CT machines have steadily increased the number of rows of detectors (slices) they deploy. The prototype 16 multi-slice scanner was introduced in 2001 and in 2004, 64 multislice scanners are on the market. These can produce an image in less than a second and thus can obtain images of the heart and its blood vessels (coronary vessels) as if frozen in time.

The earliest devices, developed in 1989, were called "SSCT", for "single-slice spiral computed tomography". In 1998, "MSCT" or "multi-slice spiral computed tomography" was introduced.[5]

Helical (or spiral) cone beam computed tomography

<templatestyles src="Module:Hatnote/styles.css"></templatestyles>

In cone-beam computed tomography (commonly abbreviated CBCT), the x-ray beam is conical.[6]

Helical (or spiral) cone beam computed tomography is a type of three-dimensional computed tomography (CT) in which the source (usually of x-rays) describes a helical trajectory relative to the object while a two-dimensional array of detectors measures the transmitted radiation on part of a cone of rays emanating from the source.

In practical helical cone beam x-ray CT machines, the source and array of detectors are mounted on a rotating gantry while the patient is moved axially at a uniform rate. Earlier x-ray CT scanners imaged one slice at a time by rotating source and one-dimensional array of detectors while the patient remained static. The helical scan method reduces the x-ray dose to the patient required for a given resolution while scanning more quickly. This is however at the cost of greater mathematical complexity in the reconstruction of the image from the measurements.

References

  1. Avinash C. Kak and Malcolm Slaney (2001). Principles of Computerized Tomographic Imaging. Society for Industrial and Applied Mathematics ISBN 978-0-89871-494-4 / ISBN 0-89871-494-X.
  2. Lua error in package.lua at line 80: module 'strict' not found.
  3. Kalender WA (1994). "Technical foundations of spiral CT" Semin Ultrasound CT MR 15: (2) 81-89.
  4. Kalender WA (1994). "Spiral or helical CT: right or wrong?" Radiology 193: (2) 583.
  5. Lua error in package.lua at line 80: module 'strict' not found.
  6. Helical Cone-Beam CT at the US National Library of Medicine Medical Subject Headings (MeSH)

External links

de:Computertomographie#Spiral- oder Helix-CT