Tihange Nuclear Power Station

From Infogalactic: the planetary knowledge core
Jump to: navigation, search
Tihange Nuclear Power Station
File:Huy, koeltorens 2007-05-01 14.57.JPG
Tihange Nuclear Power Station is located in Belgium
Tihange Nuclear Power Station
Location of Tihange Nuclear Power Station in Belgium
Country Belgium
Location Huy
Coordinates Lua error in package.lua at line 80: module 'strict' not found.
Construction began 1970
Commission date 1 October 1975
Owner(s) Electrabel
Nuclear power station
Reactor type pressurized water reactors
Reactor supplier ACLF, FRAMACEC,ACECOWEN
Power generation
Units operational 1 x 962 MW
1 x 1008 MW
1 x 1015 MW
Nameplate capacity 2,985
Annual generation 23 TWh

The Tihange Nuclear Power Station is one of the two large-scale nuclear power plants in Belgium, the other being Doel Nuclear Power Station. It is located on the right bank of the Meuse River in the Belgian district of Tihange, part of Huy municipality in the Walloon province of Liège. The primary stakeholder in the plant is the Belgian energy company Electrabel.

Reactors

The plant has three pressurized water reactors, with a total capacity of 2985 MWe and makes up 52% of the total Belgian nuclear generating capacity.[1] Its units are rated as follows:

  • Tihange 1: 962 MWe (1975)
  • Tihange 2: 1008 MWe (1983)
  • Tihange 3: 1015 MWe (1985)

The reactors were supplied by different consortia, respectively ACLF (ACECOWEN-Creusot-Loire-Framatome), FRAMACECO (Framatome-ACEC-Cockerill), ACECOWEN (ACEC-Cockerill-Westinghouse).[2]

The units were designed for an operational lifetime of 30 years. In 2003, a Belgian law concerning the closure of the Belgian nuclear reactors permitted an operational lifetime of 40 years for the three reactors in Tihange. On July 4, 2012, however, the Belgian government decided that Tihange 1 could be operated until 2025.

Incidents

On November 22, 2002, an incident occurred in Block 2 (INES 2). The reactor was shut down at this time and no longer critical. However it remained necessary for decay heat to be removed from the reactor by circulating coolant. The November 22 incident involved accidental opening of a pressure relief valve. This caused the high pressure primary coolant circuit to rapidly depressurize, therefore reducing the ability of the circuit to remove heat from the reactor (the high pressure prevents the coolant - water - from boiling), leading to possible reactor overheating and eventual meltdown. The pressure relief valve was closed again after three minutes.

On September 3, 2008 a malfunctioning fan was found in a reactor. This was classified as INES-1.[3] Also, in 2005 and 2002 there were two INES-2 incidents. And in 2001 and 1993 there were fires on the site of the nuclear power plant. Those were classified as level 0.[4]

Since 2006 there has been a leak of 0.5-2 liters of mildly radioactive water from a deactivation-bath.[5] After this was notified to the nl (Belgium Federal Agency for Nuclear Control (FANC)) Electrabel tried to find the cause of the leak. But on 11 July 2012 it became apparent that the leakage still exists. According to FANC this issue is "under control" and no radioactivity leaks outside the buildings.[6]

September 1, 2012, it became known that the Tihange 2 reactor shows signs of erosion weakening of the outer reinforced concrete mantle up to a depth of 0.3 m. Electrabel and the Belgian nuclear regulator FANC deny any immediate security risk since the reactor was already shut down for maintenance.[7]

February 23, 2015, Dutch newspaper reports on thousands of cracks well up to 6 cm according to Federaal Agentschap voor Nucleaire Controle (FANC).[8] Actual discussion still assumes the reactor to be turned on in July again. This did not happen, and in September 2015 the unit is still offline pending further investigation.

See also

References

  1. http://www.iaea.org/cgi-bin/db.page.pl/pris.powrea.htm?country=BE&sort=&sortlong=Alphabetic
  2. Lua error in package.lua at line 80: module 'strict' not found.
  3. http://archives.lesoir.be/?action=nav&gps=634657
  4. Lua error in package.lua at line 80: module 'strict' not found.
  5. Lua error in package.lua at line 80: module 'strict' not found.
  6. Lua error in package.lua at line 80: module 'strict' not found.
  7. Lua error in package.lua at line 80: module 'strict' not found.
  8. Lua error in package.lua at line 80: module 'strict' not found.

External links

  • Belgian, Dutch, German alliance against the NPP Tihange stop-tihange.org
  • Site Electrabel regarding the nuclear plants in Doel and Tihange Electrabel