Wastewater quality indicators

From Infogalactic: the planetary knowledge core
Jump to: navigation, search

Wastewater quality indicators are laboratory test methodologies to assess suitability of wastewater for disposal or re-use. Tests selected and desired test results vary with the intended use or discharge location. Tests measure physical, chemical, and biological characteristics of the waste water.

Physical characteristics

Temperature

Aquatic organisms cannot survive outside of specific temperature ranges. Irrigation runoff and water cooling of power stations may elevate temperatures above the acceptable range for some species. Temperature may be measured with a calibrated thermometer.[1]

Solids

Solid material in wastewater may be dissolved, suspended, or settled. Total dissolved solids or TDS (sometimes called filterable residue) is measured as the mass of residue remaining when a measured volume of filtered water is evaporated. The mass of dried solids remaining on the filter is called total suspended solids (TSS) or nonfiltrable residue. Settleable solids are measured as the visible volume accumulated at the bottom of an Imhoff cone after water has settled for one hour.[2] Turbidity is a measure of the light scattering ability of suspended matter in the water.[3] Salinity measures water density or conductivity changes caused by dissolved materials.[4]

Chemical characteristics

Virtually any chemical may be found in water, but routine testing is commonly limited to a few chemical elements of unique significance.

Hydrogen

Water ionizes into hydronium (H3O) cations and hydroxyl (OH) anions. The concentration of ionized hydrogen (as protonated water) is expressed as pH.[5]

Oxygen

Most aquatic habitats are occupied by fish or other animals requiring certain minimum dissolved oxygen concentrations to survive. Dissolved oxygen concentrations may be measured directly in wastewater, but the amount of oxygen potentially required by other chemicals in the wastewater is termed an oxygen demand. Dissolved or suspended oxidizable organic material in wastewater will be used as a food source. Finely divided material is readily available to microorganisms whose populations will increase to digest the amount of food available. Digestion of this food requires oxygen, so the oxygen content of the water will ultimately be decreased by the amount required to digest the dissolved or suspended food. Oxygen concentrations may fall below the minimum required by aquatic animals if the rate of oxygen utilization exceeds replacement by atmospheric oxygen.[6]

The reaction for biochemical oxidation may be written as:

Oxidizable material + bacteria + nutrient + O2 → CO2 + H2O + oxidized inorganics such as NO3 or SO4

Oxygen consumption by reducing chemicals such as sulfides and nitrites is typified as follows:

S2− + 2 O2 → SO42−
NO2 + ½ O2 → NO3

Since all natural waterways contain bacteria and nutrient, almost any waste compounds introduced into such waterways will initiate biochemical reactions (such as shown above). Those biochemical reactions create what is measured in the laboratory as the biochemical oxygen demand (BOD).

Oxidizable chemicals (such as reducing chemicals) introduced into a natural water will similarly initiate chemical reactions (such as shown above). Those chemical reactions create what is measured in the laboratory as the chemical oxygen demand (COD).

Both the BOD and COD tests are a measure of the relative oxygen-depletion effect of a waste contaminant. Both have been widely adopted as a measure of pollution effect. The BOD test measures the oxygen demand of biodegradable pollutants whereas the COD test measures the oxygen demand of biogradable pollutants plus the oxygen demand of non-biodegradable oxidizable pollutants.

The so-called 5-day BOD measures the amount of oxygen consumed by biochemical oxidation of waste contaminants in a 5-day period. The total amount of oxygen consumed when the biochemical reaction is allowed to proceed to completion is called the Ultimate BOD. The Ultimate BOD is too time consuming, so the 5-day BOD has almost universally been adopted as a measure of relative pollution effect.

There are also many different COD tests. Perhaps, the most common is the 4-hour COD.

There is no generalized correlation between the 5-day BOD and the Ultimate BOD. Likewise, there is no generalized correlation between BOD and COD. It is possible to develop such correlations for a specific waste contaminant in a specific wastewater stream, but such correlations cannot be generalized for use with any other waste contaminants or wastewater streams.

The laboratory test procedures for determining the above oxygen demands are detailed in the following sections of the "Standard Methods For the Examination Of Water and Wastewater" available at www.standardmethods.org:

  • 5-day BOD and Ultimate BOD: Sections 5210B and 5210C
  • COD: Section 5220

Nitrogen

Nitrogen is an important nutrient for plant and animal growth. Atmospheric nitrogen is less biologically available than dissolved nitrogen in the form of ammonia and nitrates. Availability of dissolved nitrogen may contribute to algal blooms. Ammonia and organic forms of nitrogen are often measured as Total Kjeldahl Nitrogen, and analysis for inorganic forms of nitrogen may be performed for more accurate estimates of total nitrogen content.[7]

Phosphates

Total Phosphorus and Phosphate, PO4-3

Phosphates enter the water ways through both non-point sources and point sources. Non-point source (NPS) pollution refers to water pollution from diffuse sources. Nonpoint source pollution can be contrasted with point source pollution, where discharges occur to a body of water at a single location. The non-point sources of phosphates include: natural decomposition of rocks and minerals, storm water runoff, agricultural runoff, erosion and sedimentation, atmospheric deposition, and direct input by animals/wildlife; whereas: point sources may include: waste water treatment plants and permitted industrial discharges. In general, the non-point source pollution typically is significantly higher than the point sources of pollution. Therefore, the key to sound management is to limit the input from both point and non-point sources of phosphate. High concentration of phosphate in water bodies is an indication of pollution and largely responsible for eutrophication.[8]

Phosphates are not toxic to people or animals unless they are present in very high levels. Digestive problems could occur from extremely high levels of phosphate.

The following criteria for total phosphorus were recommended by the U.S. Environmental Protection Agency.

  1. No more than 0.1 mg/L for streams which do not empty into reservoirs,
  2. No more than 0.05 mg/L for streams discharging into reservoirs, and
  3. No more than 0.025 mg/L for reservoirs.[9]

Phosphorus is normally low (< 1 mg/l) in clean potable water sources and usually not regulated;[10][11]

Chlorine

Chlorine has been widely used for bleaching, as a disinfectant, and for biofouling prevention in water cooling systems. Remaining concentrations of oxidizing hypochlorous acid and hypochlorite ions may be measured as chlorine residual to estimate effectiveness of disinfection or to demonstrate safety for discharge to aquatic ecosystems.[12]

Biological characteristics

Water may be tested by a bioassay comparing survival of an aquatic test species in the wastewater in comparison to water from some other source.[13] Water may also be evaluated to determine the approximate biological population of the wastewater. Pathogenic micro-organisms using water as a means of moving from one host to another may be present in sewage. Coliform index measures the population of an organism commonly found in the intestines of warm-blooded animals as an indicator of the possible presence of other intestinal pathogens.[14]

See also

References

  1. Franson, Mary Ann Standard Methods for the Examination of Water and Wastewater 14th edition (1975) APHA, AWWA & WPCF ISBN 0-87553-078-8 pp.125-126
  2. Franson, Mary Ann Standard Methods for the Examination of Water and Wastewater 14th edition (1975) APHA, AWWA & WPCF ISBN 0-87553-078-8 pp.89-98
  3. Franson, Mary Ann Standard Methods for the Examination of Water and Wastewater 14th edition (1975) APHA, AWWA & WPCF ISBN 0-87553-078-8 pp.131-137
  4. Franson, Mary Ann Standard Methods for the Examination of Water and Wastewater 14th edition (1975) APHA, AWWA & WPCF ISBN 0-87553-078-8 pp.99-100
  5. Franson, Mary Ann Standard Methods for the Examination of Water and Wastewater 14th edition (1975) APHA, AWWA & WPCF ISBN 0-87553-078-8 pp.406-407
  6. Goldman, Charles R. & Horne, Alexander J. Limnology (1983) McGraw-Hill ISBN 0-07-023651-8 p.111
  7. Franson, Mary Ann Standard Methods for the Examination of Water and Wastewater 14th edition (1975) APHA, AWWA & WPCF ISBN 0-87553-078-8 pp.406-407
  8. MacCutheon et al., 1983
  9. US EPA (1984)[full citation needed]
  10. Nduka et al., 2008
  11. WHO (1984)
  12. Franson, Mary Ann Standard Methods for the Examination of Water and Wastewater 14th edition (1975) APHA, AWWA & WPCF ISBN 0-87553-078-8 pp.309-315
  13. Franson, Mary Ann Standard Methods for the Examination of Water and Wastewater 14th edition (1975) APHA, AWWA & WPCF ISBN 0-87553-078-8 pp.685-689
  14. Franson, Mary Ann Standard Methods for the Examination of Water and Wastewater 14th edition (1975) APHA, AWWA & WPCF ISBN 0-87553-078-8 pp.875-877

Further reading

External links